Local medical AI: plenty of leaderboards, almost no evidence it works in German

Sage-Med-Preview, LingSante and Meta's clinical program all landed in the same week, and every vendor claims to be on top. We looked at what hospitals and practices actually get if they can't use the cloud. The answer: one model with no license, one MIT-licensed model that needs a lot of memory, and so far no independent German-language test for any of them.

Analysis Nov 27, 2026 9 min read Original analysis by our editors
Illustrative image, AI-generated

What this is about

In late November 2026, three pieces of medical AI news landed within a few days. Shanghai AI Laboratory released Sage-Med-Preview, a model with 35 billion parameters, of which only 3 billion are active per token. Ant Group released LingSante-3.1-air-VL (124 billion) and LingSante-3.1-flash (560 billion). And Meta showcased projects in which university hospitals use its open models. Every vendor has tables showing it in the lead.

If you run a German hospital, practice or research group that isn't allowed to send patient data to the cloud, different questions matter. Are you even allowed to use the model? Does it fit on your hardware? Has anyone independent tested it? Does it understand German discharge letters? And what does medical device law have to say? We dug into each of these.

License: one model without permission, one with MIT

Sage-Med-Preview ships with 131 GiB of weights and a technical report on arXiv, but no license. The model card doesn't name one, the GitHub repo has no LICENSE file, and the mirror under internlm doesn't either. According to OrcaRouter's blog, the GitHub API reports the license as "null". The only license anywhere in the package is the arXiv license, and that covers the paper. The base model Intern-S2-Preview is released under Apache 2.0 and is itself built on Qwen3.5. But Apache 2.0 doesn't require derivative models to carry the same license. Our take: without an explicit license, no hospital should use this model beyond lab experiments. That said, OrcaRouter notes the repo was still being changed on November 27, so a license may yet appear.

LingSante-3.1-air-VL and LingSante-3.1-flash, by contrast, are under the MIT license. It's one of the most permissive licenses around, and commercial use is allowed. For comparison, Google's MedGemma-27B is governed by its own "Health AI Developer Foundations" terms, which you have to accept before downloading.

Meta hasn't released a medical model of its own. According to Meta's post from November 23, researchers are adapting general-purpose models such as Muse Glimmer, SAM 3 and DINOv3. At LSU this has produced a VR training program, at Columbia University an analysis of cell images for rare diseases, and the Fondation Rothschild in Paris is simulating epileptic seizures. According to WBRZ, Meta is handing out $2 million to five US universities. Muse Glimmer is a general-purpose 30-billion-parameter model under Apache 2.0. According to AlphaSignal, patient data stays with the universities. Meta itself describes all the projects as "early stage".

Hardware: what realistically fits in your server room

With MoE models (Mixture of Experts: the model consists of many sub-networks, and only a few of them compute for each token), total size determines memory requirements and active size determines speed.

  • Sage-Med-Preview: The developers only tested the model on a single NVIDIA H200 (141 GB), in BF16 with 32,768 tokens of context, via vLLM with --trust-remote-code and CUDA 12.9. There are no quantized versions on Hugging Face yet, meaning no versions that store their numbers more coarsely to save space. There's no GGUF for llama.cpp either. Our math: in BF16 the weights take about 70 GB, in FP8 about 35 GB, and in 4-bit about 20 GB. But until those variants exist, you need a data center card.
  • LingSante-3.1-air-VL: According to bartowski's GGUF page, it's 248.9 GB in BF16, 78.7 GB as Q4_K_M and 63.4 GB as Q3_K_L. Image input works via a bundled mmproj file and requires llama.cpp version b12600 or later. The official MXFP4 version is 64.8 GiB. One user runs a W4A16 version at 70.85 GiB on four RTX 3090s with 24 GB each. Across 19 of their own synthetic test runs, it scored 174 out of 184 points, versus 172 for the BF16 version. That's a small test, but it suggests 4-bit costs little here. Ant lists DGX Spark and RTX Spark as local platforms. According to ITBrief, Microsoft demoed the model on a Surface Laptop Ultra, without giving memory details.
  • LingSante-3.1-flash: It has 560 billion parameters, 25 billion of them active, and handles text only. The MXFP4 version, at about 292 GiB, runs on four H20-3e cards; the FP8 version needs eight H200s. That's data center hardware for large hospitals.
  • Muse Glimmer: It's a dense 30-billion-parameter model, meaning no split into experts. Reports put it at about 18 GB in 4-bit, so it fits on a single consumer graphics card.

Independent tests: the new models are still missing

All the headline numbers for the newcomers are vendor claims. Sage-Med averages 58.26 percent across 31 public multimodal benchmarks, Hulu-Med-235B 50.99 percent. The line "beats GPT-6.2 Sol" refers to private clinical data from 14 hospitals: 57.72 versus 51.24 percent. According to OrcaRouter, that figure is based on 11 of the 14 available results. The paper itself admits an overlap problem: PET/CT images from the test set also appear in the training data. For the public benchmarks, it doesn't describe any procedure for removing such overlaps.

The clearest weakness shows up in localization, meaning marking a lesion on the image. According to the paper, Sage-Med scores 30.74 percent on MedSG-Bench (ACC@.5), versus 64.25 percent for GPT-6.2-Sol. The model card, using a different metric, gives 31.73 versus 58.83. Yet the paper's introduction still calls the performance "comparable".

For LingSante-3.1-flash, Ant claimed first place among open models on InclusionMed. Its own model card, however, says: 45.064 points, fifth out of 23 model configurations. Ant only shows the air-VL benchmarks as images, with no numbers in the text.

So far, none of the new models appear in the three major independent comparisons:

Comparison What it measures New models included? Reference scores
Medmarks (61 models, text only) 30 benchmarks, win rate no MedGemma-27B 0.502 (base Gemma 3: 0.461), Baichuan M3 0.598
MEDLAYXPLAIN (33 vision-language models, English only) Image findings in plain language no MedGemma-27B 67.2 (best medical model), Lingshu-32B 53.4, Hulu-Med-4B 46.4
HealMed (9 languages incl. German) Multilingual medical questions no Specialized models lose 13.6 to 20.8 points in low-resource languages

One interesting finding from MEDLAYXPLAIN: medical models write good findings for professionals but get worse as soon as they have to phrase things for laypeople.

German: evidence only for general-purpose models

Whether Sage-Med or LingSante handle German well is unproven. Sage-Med was tested on MMedBench, whose six languages are English, Chinese, Japanese, French, Russian and Spanish, so no German. For LingSante, Ant doesn't list any languages at all and only says performance may vary by language.

There is evidence for German exam questions, but only for general-purpose models. A study from Marburg, conducted together with the IMPP, which writes the German state medical exams, was published in npj Digital Medicine. It tested official M1 and M2 questions from 2019 to 2024. On the full M2, Kimi K2.5 was the best open model at 94.52 percent, followed by Qwen3-VL at 93.18 percent, with Gemini 3.1 Pro at 98.37 percent. On M2 questions with images, Qwen3-VL dropped to 81.71 percent. No specialized medical models were included. A study in JMIR Formative Research found 91.46 percent for GPT-5 Instant and Gemini 2.5 Flash on the fall 2024 M2, with accuracy dropping on harder questions. According to HealMed, German trails English by 2.1 to 3.8 points.

Exam questions aren't the same as everyday ward work, though. The German benchmark MedQADE scores free-text answers with physicians as reviewers, and there the five models tested landed between just 17.8 and 66 percent. FineMed-de shows that German medical fine-tuning clearly improves 7B models. But subsequently combining several models (merging) led to language mixing.

The law, and the limits of averages

The LingSante model cards state explicitly that the model is "not a medical device". Sage-Med calls itself a tool for research and development. Under the MDR, the EU Medical Device Regulation, what counts is the intended purpose, meaning what the system is meant to do. Software that provides information for diagnostic or therapeutic decisions falls into at least Class IIa under Rule 11. At that point a notified body has to assess it. If you use a research model in-house for diagnoses, you become the manufacturer yourself. The in-house exemption under Art. 5(5) MDR comes with strict conditions, explained in the guidance document MDCG 2023-1. Under the Digital Omnibus (Regulation (EU) 2026/1744), the AI Act's high-risk obligations for AI in medical devices only apply from August 2, 2028. The transparency obligation under Art. 50, which requires informing users that AI is being used, has applied since August 2026, however.

German hospitals are already showing that local models work day to day. UKB-GPT at University Hospital Bonn uses open models for more than 1,000 users, with no internet connection. UKE in Hamburg uses the Orpheus speech recognition system, and University Hospital Leipzig runs UKL-GPT.

A paper by Florian Odi Stummer (University Hospital Halle) also shows what benchmark averages hide. In 11,475 synthetic patient records, 46.9 percent of the diagnostic vocabulary disappeared when diagnoses with less than 1 percent frequency were removed. That affected 24.4 percent of the records, and 34 of the removed diagnoses belonged to ongoing treatments. The author stresses that what was measured is information loss, not accuracy on actual patients.

Our verdict

Sage-Med-Preview LingSante-3.1-air-VL LingSante-3.1-flash Muse Glimmer (Meta) MedGemma-27B (reference)
License none MIT MIT Apache 2.0 HAI-DEF terms
Memory tested on H200 (BF16), no quants ~79 GB (Q4_K_M), 64.8 GiB MXFP4 ~292 GiB (MXFP4) ~18 GB (4-bit) approx. 18 GB (4-bit, our estimate)
Independent tests none none only OrcaRouter's claim (23.3% MLCR-AA), unverifiable no medical ones found Medmarks, MEDLAYXPLAIN, HealMed
Evidence for German none (MMedBench has no German) none none none included in HealMed, no separate score
MDR status research, no CE "not a medical device" "not a medical device" general-purpose model not for direct diagnosis

Our take: for local deployment, LingSante-3.1-air-VL is currently the most practical candidate. The license is clear, GGUF versions exist, and it runs on systems with roughly 80 to 128 GB of memory. Sage-Med is interesting for research, but without a license and without quantization it isn't ready for use. For German text, only general-purpose open models have so far been shown to reach state-exam level. If you want to deploy a medical model, test it on your own German cases first.

Sources

#medical ai#open-weights#license#mdr#benchmarks#german

Ask the AI assistant

Questions about this article, installation or background? Our assistant knows this page and runs on our own machine, not in someone else's cloud.

Connecting …

The Assistant is an AI (Gemma 4) and can make mistakes – please check important details against the source. Questions are used only to generate an answer and are deleted after one hour. Please don't enter any personal data.

Comments

What do you think? Already tried it? Write it here, no sign-up needed.

  1. Loading comments …

Comments are public. Links aren't allowed, and we delete abusive posts. You can delete your own comment at any time in this browser. Learn more in the Privacy Policy.